Bandwidth
DC-15MHz
-
Current
DC/AC RMS 150A
-
Rise time
≤24ns
-
Range sensitivity
0.1V/A 0.01V/A
-
Typical DC Accuracy
士1%+20mA@0.1V/A 士1%+200mA@0.01V/A
-
Maximum operating voltage
600V CATII 300V CATIII
-
Zero adjustment mode
Automatic
-
Power supply modenction
12V/2A power supply
-
Jaw diameter
Φ19mm
-
Interface Type
BNC
-
Weight
523g
-
Overall dimension
Control box: 109mm x 24.2mm x 57.8mm //Current clamp: 170mm x 30mm x 65mm
-
Delay time
Probe host 37ns //BNC 5ns (line length 1 m)
-
Cable length
Control box to BNC connector cable length: 0.9m// Cable length from control box to current clamp: 1.4m
-
-
-
Bandwidth
DC-100MHz
-
Current
DC/AC peak 40A
-
Rise time
≤3.5ns
-
Range sensitivity
50mV/A
-
Typical DC Accuracy
士2%rdg
-
Maximum operating voltage
CATI 400V
-
Zero adjustment mode
Automatic
-
Power supply modenction
5V/2A power supply
-
Jaw diameter
Φ4.5mm
-
Interface Type
BNC
-
Weight
200g
-
Overall dimension
230mmx45.5mmx24.5mm
-
Maximum pulse current
50A(TP≤10uS)
-
Noise
≤1mVrms
-
Linearity
±1%
-
Delay time
20ns
-
Cable length
130cm
-
-
-
Bandwidth
DC-6MHz
-
Current
DC/AC RMS 300A
-
Rise time
≤58ns
-
Range sensitivity
0.1V/A 0.01V/A
-
Typical DC Accuracy
士1%+20mA@0.1V/A 士1%+200mA@0.01V/A
-
Maximum operating voltage
600V CATII 300V CATIII
-
Zero adjustment mode
Automatic
-
Power supply modenction
12V/2A power supply
-
Jaw diameter
Φ19mm
-
Interface Type
BNC
-
Weight
523g
-
Overall dimension
Control box: 109mm x 24.2mm x 57.8mm //Current clamp: 170mm x 30mm x 65mm
-
Delay time
Probe host 41ns //BNC 5ns (line length 1 m)
-
Cable length
Control box to BNC connector cable length: 0.9m// Cable length from control box to current clamp: 1.4m
-
-
-
Bandwidth
DC-5MHz
-
Current
DC/AC RMS 500A
-
Rise time
≤70ns
-
Range sensitivity
0.1V/A 0.01V/A
-
Typical DC Accuracy
士1%+10mA@0.1V/A 士1%+100mA@0.01V/A
-
Maximum operating voltage
600V CATII 300V CATIII
-
Zero adjustment mode
Automatic
-
Power supply modenction
12V/2A power supply
-
Jaw diameter
Φ19mm
-
Interface Type
BNC
-
Weight
523g
-
Overall dimension
Control box: 109mm x 24.2mm x 57.8mm //Current clamp: 170mm x 30mm x 65mm
-
Delay time
Probe host 42ns //BNC 5ns (line length 1 m)
-
Cable length
Control box to BNC connector cable length: 0.9m// Cable length from control box to current clamp: 1.4m
-
-
-
Bandwidth
DC-5MHz
-
Current
DC/AC RMS 500A
-
Rise time
≤70ns
-
Range sensitivity
0.1V/A 0.01V/A
-
Typical DC Accuracy
士1%+20mA@0.1V/A 士1%+200mA@0.01V/A
-
Maximum operating voltage
600V CATII 300V CATIII
-
Zero adjustment mode
Automatic
-
Power supply modenction
12V/2A power supply
-
Jaw diameter
Φ19mm
-
Interface Type
BNC
-
Weight
523g
-
Overall dimension
Control box: 109mm x 24.2mm x 57.8mm //Current clamp: 170mm x 30mm x 65mm
-
Delay time
Probe host 42ns //BNC 5ns (line length 1 m)
-
Cable length
Control box to BNC connector cable length: 0.9m// Cable length from control box to current clamp: 1.4m
-
-
-
Bandwidth
DC-30MHz
-
Current
DC/AC RMS 50A
-
Rise time
≤11.7ns
-
Range sensitivity
0.1V/A 1V/A
-
Typical DC Accuracy
士1%+1mA@1V/A 士1%+10mA@0.1V/A
-
Maximum operating voltage
600V CATII 300V CATIII
-
Zero adjustment mode
Automatic
-
Power supply modenction
12V/2A power supply
-
Jaw diameter
Φ5mm
-
Interface Type
BNC
-
Weight
255g
-
Overall dimension
Current clamp handle size (length * width * height):176mm x 39.5mm x 18mm// Control box size (length * width * height):91.5mm x 40mm x 26.5mm
-
Delay time
Probe host 14ns //BNC 5ns (line length 1 m)
-
Cable length
Control box to BNC connector cable length: 1m// Cable length from control box to current clamp: 1m
-
-
-
Bandwidth
DC-120MHz
-
Current
DC/AC RMS 30A
-
Rise time
≤2.92ns
-
Range sensitivity
0.1V/A 1V/A
-
Typical DC Accuracy
士1%+1mA@1V/A 士1%+10mA@0.1V/A
-
Maximum operating voltage
600V CATII 300V CATIII
-
Zero adjustment mode
Automatic
-
Power supply modenction
12V/2A power supply
-
Jaw diameter
Φ5mm
-
Interface Type
BNC
-
Weight
255g
-
Overall dimension
Current clamp handle size:176mm x 39.5mm x 18mm// Control box size:91.5mm x 40mm x 26.5mm
-
Delay time
Probe host 14ns //BNC 5ns (line length 1 m)
-
Cable length
Control box to BNC connector cable length: 1m// Cable length from control box to current clamp: 1m
-
-
-
Bandwidth
DC-50MHz
-
Current
DC/AC RMS 50A
-
Rise time
≤7ns
-
Range sensitivity
0.1V/A 1V/A
-
Typical DC Accuracy
士1%+1mA@1V/A 士1%+10mA@0.1V/A
-
Maximum operating voltage
600V CATII 300V CATIII
-
Zero adjustment mode
Automatic
-
Power supply modenction
12V/2A power supply
-
Jaw diameter
Φ5mm
-
Interface Type
BNC
-
Weight
255g
-
Overall dimension
Current clamp handle size (length * width * height):176mm x 39.5mm x 18mm// Control box size (length * width * height):91.5mm x 40mm x 26.5mm
-
Delay time
Probe host 14ns //BNC 5ns (line length 1 m)
-
Cable length
Control box to BNC connector cable length: 1m// Cable length from control box to current clamp: 1m
-
-
-
Bandwidth
DC-50MHz
-
Current
DC/AC RMS 30A
-
Rise time
≤7ns
-
Range sensitivity
0.1V/A 1V/A
-
Typical DC Accuracy
士1%+5mA@1V/A 士1%+20mA@0.1V/A
-
Maximum operating voltage
600V CATII 300V CATIII
-
Zero adjustment mode
Automatic
-
Power supply modenction
12V/2A power supply
-
Jaw diameter
Φ5mm
-
Interface Type
BNC
-
Weight
255g
-
Overall dimension
Current clamp handle size :176mm x 39.5mm x 18mm// Control box size :91.5mm x 40mm x 26.5mm
-
Delay time
Probe host 14ns //BNC 5ns (line length 1 m)
-
Cable length
Control box to BNC connector cable length: 1m// Cable length from control box to current clamp: 1m
-
-
-
Bandwidth
DC-30MHz
-
Current
DC/AC RMS 30A
-
Rise time
≤11.7ns
-
Range sensitivity
0.1V/A 1V/A
-
Typical DC Accuracy
士1%+5mA@1V/A 士1%+20mA@0.1V/A
-
Maximum operating voltage
600V CATII 300V CATIII
-
Zero adjustment mode
Automatic
-
Power supply modenction
12V/2A power supply
-
Jaw diameter
Φ5mm
-
Interface Type
BNC
-
Weight
255g
-
Overall dimension
Current clamp handle size (length * width * height):176mm x 39.5mm x 18mm// Control box size (length * width * height):91.5mm x 40mm x 26.5mm
-
Delay time
Probe host 14ns //BNC 5ns (line length 1 m)
-
Cable length
Control box to BNC connector cable length: 1m// Cable length from control box to current clamp: 1m
-