Language:English
Oscilloscope Probes
Home > Mall > Oscilloscope Probes
  • ETA56053A  Current probe
    • Bandwidth

      DC-30MHz

    • Current

      DC/AC RMS 50A

    • Rise time

      ≤11.7ns

    • Range sensitivity

      0.1V/A 1V/A

    • Typical DC Accuracy

      士1%+1mA@1V/A 士1%+10mA@0.1V/A

    • Maximum operating voltage

      600V CATII 300V CATIII

    • Zero adjustment mode

      Automatic

    • Power supply modenction

      12V/2A power supply

    • Jaw diameter

      Φ5mm

    • Interface Type

      BNC

    • Weight

      255g

    • Overall dimension

      Current clamp handle size (length * width * height):176mm x 39.5mm x 18mm// Control box size (length * width * height):91.5mm x 40mm x 26.5mm

    • Delay time

      Probe host 14ns //BNC 5ns (line length 1 m)

    • Cable length

      Control box to BNC connector cable length: 1m// Cable length from control box to current clamp: 1m

    $1,050.00
  • ETA560312A  Current probe
    • Bandwidth

      DC-120MHz

    • Current

      DC/AC RMS 30A

    • Rise time

      ≤2.92ns

    • Range sensitivity

      0.1V/A 1V/A

    • Typical DC Accuracy

      士1%+1mA@1V/A 士1%+10mA@0.1V/A

    • Maximum operating voltage

      600V CATII 300V CATIII

    • Zero adjustment mode

      Automatic

    • Power supply modenction

      12V/2A power supply

    • Jaw diameter

      Φ5mm

    • Interface Type

      BNC

    • Weight

      255g

    • Overall dimension

      Current clamp handle size:176mm x 39.5mm x 18mm// Control box size:91.5mm x 40mm x 26.5mm

    • Delay time

      Probe host 14ns //BNC 5ns (line length 1 m)

    • Cable length

      Control box to BNC connector cable length: 1m// Cable length from control box to current clamp: 1m

    $2,121.00
  • ETA56055A  Current probe
    • Bandwidth

      DC-50MHz

    • Current

      DC/AC RMS 50A

    • Rise time

      ≤7ns

    • Range sensitivity

      0.1V/A 1V/A

    • Typical DC Accuracy

      士1%+1mA@1V/A 士1%+10mA@0.1V/A

    • Maximum operating voltage

      600V CATII 300V CATIII

    • Zero adjustment mode

      Automatic

    • Power supply modenction

      12V/2A power supply

    • Jaw diameter

      Φ5mm

    • Interface Type

      BNC

    • Weight

      255g

    • Overall dimension

      Current clamp handle size (length * width * height):176mm x 39.5mm x 18mm// Control box size (length * width * height):91.5mm x 40mm x 26.5mm

    • Delay time

      Probe host 14ns //BNC 5ns (line length 1 m)

    • Cable length

      Control box to BNC connector cable length: 1m// Cable length from control box to current clamp: 1m

    $1,264.00
  • ETA56035U  Current probe
    • Bandwidth

      DC-50MHz

    • Current

      DC/AC RMS 30A

    • Rise time

      ≤7ns

    • Range sensitivity

      0.1V/A 1V/A

    • Typical DC Accuracy

      士1%+5mA@1V/A 士1%+20mA@0.1V/A

    • Maximum operating voltage

      600V CATII 300V CATIII

    • Zero adjustment mode

      Automatic

    • Power supply modenction

      12V/2A power supply

    • Jaw diameter

      Φ5mm

    • Interface Type

      BNC

    • Weight

      255g

    • Overall dimension

      Current clamp handle size :176mm x 39.5mm x 18mm// Control box size :91.5mm x 40mm x 26.5mm

    • Delay time

      Probe host 14ns //BNC 5ns (line length 1 m)

    • Cable length

      Control box to BNC connector cable length: 1m// Cable length from control box to current clamp: 1m

    $750.00
  • ETA56033U  Current probe
    • Bandwidth

      DC-30MHz

    • Current

      DC/AC RMS 30A

    • Rise time

      ≤11.7ns

    • Range sensitivity

      0.1V/A 1V/A

    • Typical DC Accuracy

      士1%+5mA@1V/A 士1%+20mA@0.1V/A

    • Maximum operating voltage

      600V CATII 300V CATIII

    • Zero adjustment mode

      Automatic

    • Power supply modenction

      12V/2A power supply

    • Jaw diameter

      Φ5mm

    • Interface Type

      BNC

    • Weight

      255g

    • Overall dimension

      Current clamp handle size (length * width * height):176mm x 39.5mm x 18mm// Control box size (length * width * height):91.5mm x 40mm x 26.5mm

    • Delay time

      Probe host 14ns //BNC 5ns (line length 1 m)

    • Cable length

      Control box to BNC connector cable length: 1m// Cable length from control box to current clamp: 1m

    $686.00
  • ETA56036A  Current probe
    • Bandwidth

      DC-60MHz

    • Current

      DC/AC RMS 30A

    • Rise time

      ≤5.84ns

    • Range sensitivity

      0.1V/A 1V/A

    • Typical DC Accuracy

      士1%+1mA@1V/A 士1%+10mA@0.1V/A

    • Maximum operating voltage

      600V CATII 300V CATIII

    • Zero adjustment mode

      Automatic

    • Power supply modenction

      12V/2A power supply

    • Jaw diameter

      Φ5mm

    • Interface Type

      BNC

    • Weight

      255g

    • Overall dimension

      Current clamp handle size (length * width * height):176mm x 39.5mm x 18mm// Control box size (length * width * height):91.5mm x 40mm x 26.5mm

    • Delay time

      Probe host 14ns //BNC 5ns (line length 1 m)

    • Cable length

      Control box to BNC connector cable length: 1m// Cable length from control box to current clamp: 1m

    $1,479.00
  • ETA560310U  Current probe
    • Bandwidth

      DC-100MHz

    • Current

      DC/AC RMS 30A

    • Rise time

      ≤3.5ns

    • Range sensitivity

      0.1V/A 1V/A

    • Typical DC Accuracy

      士1%+5mA@1V/A 士1%+20mA@0.1V/A

    • Maximum operating voltage

      600V CATII 300V CATIII

    • Zero adjustment mode

      Automatic

    • Power supply modenction

      12V/2A power supply

    • Jaw diameter

      Φ5mm

    • Interface Type

      BNC

    • Weight

      255g

    • Overall dimension

      Current clamp handle size:176mm x 39.5mm x 18mm// Control box size:91.5mm x 40mm x 26.5mm

    • Delay time

      Probe host 14ns //BNC 5ns (line length 1 m)

    • Cable length

      Control box to BNC connector cable length: 1m// Cable length from control box to current clamp: 1m

    $1,479.00
  • ETA5215B   High voltage differential probe
    • Bandwidth

      200MHz

    • Rise time

      ≤1.75ns

    • Accuracy

      ±2%

    • Attenuation ratio

      50X;500X

    • Voltage range

      ±1500V DC+Peak AC

    • Common mode voltage

      ±1500V DC+ Peak AC

    • Maximum input voltage to ground

      600V CAT III 1000V CAT II Vrms

    • Delay time

      14ns

    • Input impedance

      Single-ended to ground 5MΩ ± 1%;
      Two input terminals 10MΩ ± 1%

    • Input capacitance

      Single-ended to ground <4pF ;Two input terminals <2pF

    • CMRR

      DC > 80dB ;100KHz > 60dB; 1MHZ > 50dB; 3.2MHz > 30dB; 50MHz > 26dB

    • Noise level

      50X < 50mVrms ; 500X < 300mVrms

    • Overload indication voltage threshold

      50X ≥ 150V; 500X ≥ 1500V

    • Bandwidth Limit (5MHZ)

      ≥-3dB @ 5MHZ

    • Overload indicator lamp

      Red Light

    • Overload alarm sound

      support; optionally off

    • Bias adjustable function

      Support

    • Terminal load requirements

      ≥100kΩ

    • Power

      USB 5V/1A Adapter

    $7,049.00
  • ETA5220A   Single-ended high-voltage probe
    • Attenuation ratio

      100:1

    • Bandwidth

      DC to 100MHz

    • Rise time

      3.5nS

    • Input impedance

      300MΩ

    • Compensation range

      10 to 35 pF

    • Input voltage

      20KV DC/Peak AC < 30s

    • Temperature and humidity

      0℃ to 50 ℃;85% RH

    • Overall length

      2m

    $380.00
  • ETA5230A   Single-ended high-voltage probe
    • Attenuation ratio

      1000:1

    • Bandwidth

      DC to 50MHz

    • Rise time

      3.5nS

    • Input impedance

      900MΩ

    • Compensation range

      10 to 35 pF

    • Input voltage

      20KV DC/Peak AC < 30s

    • Temperature and humidity

      0℃ to 40 ℃;80% RH

    • Overall length

      2m

    $0.00